Statistiche gratis

I NOSTRI SERVIZI

We offer a wide range of services, from installation, to improvements, to maintenance and emergency repairs. Safety is our priority. We work safely and are committed to creating a safe environment for every customer. We don't save money and we don't take shortcuts. Customer satisfaction is our priority. LAQGIMPIANTI SRLS carries out works on: DESIGN – INSTALLATION – MAINTENANCE systems for: 1. ELECTRICAL SYSTEMS (CIVIL AND INDUSTRIAL) 2. LIGHTING SYSTEMS 3. RADIO, TELEVISION AND ELECTRONIC SYSTEMS 4. ATMOSPHERIC DISCHARGE PROTECTION SYSTEMS 5. WATER AND SEWERAGE SYSTEMS 6. SYSTEMS Thermal 7. Conditioning and ventilation systems 8. 6 fuel gas systems 9. Solar energy systems 10. Firefighting systems 11. Safety signs 12. Alarm and video surveillance systems 13. maintenance condominiums 14: home automation and home automation; 15: ANTI-INTRUSION SYSTEMS; 16: VIDEO SURVEILLANCE SYSTEMS; 17: DOOR PHONE AND VIDEO DOOR PHONE SYSTEMS; 18: LIGHTS FOR PARTIES, WEDDINGS, RELIGIOUS OCCASIONS AND CHRISTMAS DECORATIONS; 19: ELECTRIFICATION OF BELL TOWERS AND CLOCKS Professionalism and seriousness in the services requested.

SAFETY IN THE USE OF THE SYSTEMS

Domestic accidents, of which children are often victims, can be caused both by electrical or gas systems that do not comply with the law, and by the careless use of household appliances. In every home there are numerous power sockets which, if not adequately protected, can cause electrocution, especially for children; faulty household appliances cause dangerous current leakages; poorly constructed systems or electrical devices used near water can cause accidents, often fatal. Gas can also be dangerous and without due attention can cause dangerous accidents; Here's how to behave with the electrical system while safeguarding safety: Have the earthing system and the "life-saving" differential switch installed. The earthing system and the life-saving device are essential elements for safety in the use of electrical appliances. The earthing system disperses the current into the ground in the event that the insulation of the devices is defective, thus avoiding the risk of electrocution. The circuit breaker blocks the passage of electricity. Don't improvise as technicians. Don't try to repair cables, plugs, sockets or lamp holders with adhesive or insulating tape: it's an unnecessary risk. Remember that poorly carried out repairs can be a source of serious dangers. Damaged plugs, sockets and cables must be replaced. When you change a light bulb, turn off the main switch. Before starting any work on the electrical system, even the simplest one, it is necessary to turn off the main switch. Never use a light bulb with a higher wattage than that indicated on the fixture. When using an extension cord, unplug it first. If you have finished using an extension cord, turn off the appliance and unplug it from the wall socket first. In this way you avoid having parts of the electrical wire live. Do not remove the plug by pulling the cord Never pull the cord to remove a plug from the socket: you run the risk of "ripping" the socket from the wall, breaking the cord or ruining the insulation of the wires and thus causing a short circuit. Connect only one appliance to each socket Always connect only one appliance to a socket and do not use multiple sockets to connect different appliances at the same time. This could cause a short circuit or even a fire. Do not use household appliances with wet hands or bare feet. Do not use household appliances with wet hands or bare feet: in the event of a "shock", wet hands and bare feet facilitate the passage of electric current through the body, this can also cause consequences. very serious. Do not wind the electric wire on the iron while it is still hot. The high temperature of the soleplate damages the insulation of the cable: wait until the iron is cold before rewinding the wire. Unplug before putting water in the steam iron. Before adding water to the steam iron it is good practice to turn off the iron and unplug it. Water could wet a damaged wire and cause leakage current. Use electricity carefully in the bathroom When you are in contact with water, do not use appliances connected to the mains (radios, heaters, hairdryers, razors...). A radio or lamp, connected to the mains, falling into the tub while taking a bath causes fatal consequences. To be safe, turn off the water heater. It is good practice to turn off the switch on the electric water heater before entering the tub or getting in the shower. Do not use electrical appliances when you are wet. Dry hands and slippers on your feet are essential for shaving with an electric razor or drying your hair safely. To clean small household appliances, do not immerse the electrical parts in water. Leaks in the mechanism and electrical parts could cause a short circuit the next time you turn them on. Do not touch halogen lamps with your fingers. Always use a cloth to avoid damaging the lamp and burning your fingers. Be careful with outdoor lights. Normal lamp holders are not suitable for outdoors. Equipment to be installed outdoors must have special protection against humidity and must be expressly guaranteed by the manufacturer for outdoor environments. Have safety sockets installed To avoid dangers, have safety sockets with the IMQ mark installed. The introduction of foreign bodies is prevented into the holes in these sockets. If you have old-style power sockets and there are children in the house, insert the appropriate insulating caps on all sockets.
Get a free quote

Electrical systems

Whenever you deal with electricity, you need an expert's opinion. The simplest solutions are never the safest. We will come to your home and take care of your electrical systems, so as to eliminate all your worries.
Get a free quote

Water-thermal systems

Our commitment is to seek optimal housing solutions through services such as: »FREE planning and estimates »Home surveys »Consultation for hydraulic/thermal systems »Pre- and post-installation assistance »Custom-made and restoration works Correct installation of the heating systems plumbing and heating will save you money and improve the appearance of your home. We provide a variety of high-quality options. furthermore, with our instruments we identify the exact location of underground metal pipes at any depth, regardless of their diameter, and detect the exact point of underground or wall fluid leaks. hot and cold water pipes, gas pipes, heating systems heating, fire prevention systems, swimming pools, water lines, fluids in general and much more.
Get a free quote

lights for parties and weddings

Lighting is what most characterizes an event. The lights can arouse strong emotions. The lights of LaQgimpianti srls are suitable for both religious celebrations and summer festivals. Make the atmosphere of your wedding unique with special lights: discover all the lighting decoration solutions for weddings and other events, we will offer you a quote so as to give you the opportunity to make an informed decision based on your budget.
Get a free quote

Heating and air conditioning

Regular maintenance of your heating and air conditioning systems is important to the health and safety of your family. If you need to resolve a problem or simply want to request a regular check-up, contact us and we will help you.
Get a free quote

Calculation of BTU and kW power of an air conditioner

CONDITIONING

Do you need to buy and have air conditioners installed? How many BTUs do you need for a room in square meters? What is the power in kW of an air conditioner? We answer your questions about calculating BTUs for an air conditioner per square meter and see an example on how to calculate how many BTUs per square meter and the power of an air conditioner in kW (kilo watts).

To do this we will explain what BTUs are for sizing an air conditioner and what the BTU calculation formula is. Another useful formula is the conversion of the power of an air conditioner (in fact the power is measured with BTU) from BTU to Watt, in this way you can best choose your system with a btu or kw calculation. To conclude, let's get practical with a table to understand how to calculate the BTUs for an apartment per square meter or to heat a room.

- What are BTUs: power of an air conditioner


- Formula for calculating BTU and power in kW for sizing an air conditioner

- Air conditioner power kW and BTU

- How to calculate BTUs for an apartment

How many BTUs per square meter

    Precise BTU calculation: choose a professional for air conditioner sizing

What are BTUs: power of an air conditioner


To calculate the power of an air conditioner, BTU/h (British Thermal Unit per hour of operation) is used as a unit of energy measurement. The BTU identifies the cooling power of an air conditioning system for one hour of operation. Technically, one BTU is the amount of heat required to raise the temperature of 1 pound (i.e. 453.59237 grams) of water from 39°F to 40°F (i.e. 3.8°C to 4.4°C).

All brands of air conditioners provide the power expressed in BTU/hour for each splitter (generally we simply talk about btu). They typically range from 7,000 btu up to 14,000 btu for the most powerful splitters.


Formula for calculating BTU and power in kW for sizing an air conditioner

To make a quick calculation of the BTUs for sizing an air conditioner we must first calculate the cooling power of an air conditioner in Watts and then transform it into BTUs. The simplified formula for Watt power is:

Watt Power Calculation = K x Width x Length x Height

Correctly the calculation of the power of air conditioners in Watts starts from the calculation of the cubic meters of the volume of air to be cooled or heated present in a room and we from the square meters. Then for simplicity we talk about calculating BTUs in square meters because on average the height of a home ceiling is almost always 2.9 m.

In the formula for calculating the cooling power we find a constant K which is a standard parameter, which is used with two values:

    K = 25 for the calculation to cool a houseK = 36 for the calculation to heat a house

Since 1 Watt equals 3.4 BTU/hour, to go from Watt to BTU/hour we need to multiply the result by 3.4. Here is the formula for calculating BTUs starting from the power in kW of an air conditioner.

BTU Calculation = Watt Power Calculation x 3.4

Let's see an example of BTU calculation to cool a 12 m2 (3x4) room with a height of 2.9 m:

    Calcolo Watt: 25 (k) x 3 m x 4 m x 2,9 m = 870 WattCalcolo BTU: 810 watt x 3,4 = 2.958 BTU/h

From these simplified calculations you need to buy an air conditioner with at least 3,000 BTU.

These are quick and simplified calculations.


Air conditioner power kW and BTU

As we saw before, to understand the electricity consumption of each individual splitter, which has a certain power expressed in BTU, I have to convert the btu value into watts. Watt measures how much an appliance consumes per hour. So we need to transform btu/hour into watt/hour or, better yet, into kilowatt/hour.

To make this transformation it is decidedly simple, as we have seen 1 Watt = 3,416 Btu (before we had a rounded figure). At this point we need to divide the power in BTUs by 3.416 to find the power in kW. Let's see some examples to calculate the power in kilowatts starting from BTUs:

Calculation of air conditioner power in kW from BTUHourly consumption in kW7,000 BTU air conditioner2 kW/h9,000 BTU air conditioner2.6 kW/h12,000 BTU air conditioner3.5 kW/h14,000 BTU air conditioner4.1 kW/h

Counting the kW of power of your air conditioners has a dual utility for understanding:

    The electrical consumption of your home air conditioning system to also evaluate the energy power needed. If you have an obligation to carry out periodic energy efficiency checks on your air conditioning system and if you need to keep the single system booklet in order.

With these examples of calculating btu in kW, we now know how to answer the question "how many kW are 12,000 btu?". The answer is 3.5Kw.

How to calculate BTUs for an apartment


Once we understand what BTUs are, let's see how to calculate the power needed for our air conditioners. The purpose is how to calculate the BTUs for an apartment to cool the house based on square meters.

First we need to have the measurements of the house to calculate the volume of the house, i.e. the square meters and the internal height.

Subsequently, as we saw in the initial chapter, we must multiply the volume by a factor K which is used in this way:

    Cooling an apartment K is 25. Heating an apartment K is 36.

The result of this simple operation provides us with the necessary cooling capacity expressed in calories/hour (technically they would be refrigerators/hour).

Finally we can convert the power expressed in Kcal (kilocalories) into BTU or Watt. Taking into account that 1 Watt = 0.860 Kcal/h and 1 BTU= 0.252 Kcal/h.

How many BTUs per square meter

Let's see some examples to answer the questions: how many btu per square meter? As we saw initially we should talk about cubic meters and not square metres, but for simplicity we always talk about square meters considering the average height of a home ceiling of 2.9 m.

We have prepared a simple table that applies the formulas for calculating btu and kW. The table is developed on the basis of the square meters of the house or a room. Let's start by understanding how many BTUs per 20 m2 and then move on to larger sizes of 20 m2, 30 m2, 40 m2, 50 m2, 60 m2 and so on.

Table for calculating BTU per m²How many BTU per m²How many Kwatts per m²20 m²5,0001,530 m²8,0002,340 m²11,0003,250 m²13,0003,860 m²16,0004,770 m²19,0005,680 m²21,0006,190 m²24,0007 ,0100 m27.0007,9110 m230.0008,8120 m232.0009,4

From the previous table we can give examples of typical sizes (50, 70 and 100 m2) and the number of air conditioners to install. Commercial air conditioners generally have ratings of 7,000, 9,000 or 12,000 BTU.

How many BTUs per 50 m2

In this case, to know how many BTUs to calculate the power of the air conditioner for 50 m2, the starting value is 13,000 BTUs. In this case we have two hypotheses, use a single 12,000 BTU air conditioner but it will be difficult to air condition the house well, or choose two 7,000 BTU air conditioners. Therefore, having to evaluate how many BTUs per 50 m2, the number of air conditioners to install is important.

How many BTUs per 70 m2

A 70m2 house can consist of two bedrooms, a bathroom, a kitchen and a living room. For 70 m2 you will need 3 air conditioners, two for the rooms and one for the living room. Let's avoid placing them in the bathroom and kitchen. The BTU calculation for 70 m2 is approximately 19,000 BTU. Overall we can put three 7,000 BTU air conditioners. This means that if they ask you how many BTUs per 70 m2 the minimum value is 19,000 BTUs but then it also depends on how many splitters you need to install.

Air conditioner power for 100 m2

In the previous table we have rounded the BTUs and Kw to easily understandable measurements. For example, the air conditioner power per 100 m2 is approximately 24,650 BTU, for simplicity in the table we have reported 27,000 BTU per 100 m2, increasing the estimate by 10%. For a 100 m2 apartment we can install 4 splitters, one with 9,000 BTU and the others with 7,000. In this case the installed power per 100 m2 is 30,000 BTU.

Precise BTU calculation: choose a professional for air conditioner sizing


The values expressed by the formulas are used exclusively to give you an idea of how many BTUs are needed for each room in the house. For precise calculations before buying any air conditioner, it is essential to rely on a professional installer. An installer can help you with the final calculation of BTUs, to understand how many air conditioners or individual splitters are needed, and what power you need in each room of the house.

Once the BTU calculation has been defined, the professional is able to evaluate other fundamental aspects with an inspection:

    Exposure to the sun of the various rooms of the house Any heat sources present also deriving from nearby apartments The number of windows How many people live in the house; Household appliances present to make load assessments Other data about your house

All these parameters influence the performance and comfort of air conditioners and which only a professional installer is able to do.




Safety

Installing security devices such as cameras and alarms requires special skills. We offer a wide range of solutions, from CCTV cameras and motion sensors to fire and home alarms.
Get a free quote

Maintenance of safety systems

Security systems: why maintenance is important

 

Once security systems, a video surveillance system, an anti-intrusion system or perimeter sensors have been installed, we must take into account that it will be necessary to carry out scheduled maintenance over time.

 

Maintenance of security systems is often underestimated.

In fact, it is thought that after having chosen, installed and tested the new system, it no longer needs checks and controls.

There is no bigger mistake.

We must remember that SAFETY systems are made up of various components, assembled and connected to each other.

Think of a video surveillance system, generally composed of a DVR, or digital video record, i.e. a digital image recorder with the support of a hard disk, which can be connected to one or more cameras (generally up to 64).

Another example is anti-intrusion security systems.

Think of the one via wire or via radio, in which we identify not only the heart of the alarm and therefore the control panel, but also the related infrared sensors, or magnetic contacts for doors and windows, opening keys and tags, remote controls, or external perimeter sensors and so on.

Ultimately, a security system is the result of a series of variables to be constantly kept under control.

So why schedule maintenance if our system is perfectly functional?

There are various reasons, including certainly the slow aging of the components themselves. In fact, the main cause of malfunction of the systems mentioned is to be found in slow wear.

 

 

Battery

The components that require the most maintenance are primarily the batteries.

In fact, security systems are equipped with numerous batteries, such as the control unit itself, or the individual infrared sensors, we find them in the magnetic contacts but also in the external sensors.

Batteries are susceptible to degradation over time, they can leak highly corrosive acid or overheat or in the worst case scenario catch fire.

They generally have a duration of 3 years, before which it is advisable to replace them.

 

Sensors

The sensors, whether internal or external, are calibrated during installation according to the specifications of the rooms and their surroundings.

We will certainly never erect a column inside the house, which would act as a shield for the sensor, but over time we could still change the arrangement of the furniture or insert shelves or plants on the ceiling, thus creating barriers that had not previously been budgeted, affecting the efficiency of the sensors themselves.

It would affect not only the protective cover, but inevitably over time we could detect problems with wear, opacity of the lenses or cracks in them.

This is the major cause of replacing sensors, especially external ones, because they are subject to bad weather, disturbances, insects, sun and high temperatures.

 

 

Technical maintenance

The technician called to carry out maintenance on your security systems will have to:

    check all the batteries in the system; check the operation of the sensors and their calibration; check the focus of each camera; check the connections and transmission of alarms; check the calibration of the perimeter barriers; check the video recordings and back up systems of the images.

 

The LAQGIMPIANTI staff of the various offices are always available thanks to remote assistance, for the following services:

– Modification of the programming parameters of your system; – Verification and resolution of reported anomalies; – Support for every request on the functioning of the various systems.

Therefore we also offer our customers a scheduled maintenance service for the systems, to ensure full efficiency thanks to the periodic verification of the regular functioning of all devices and components.


Share by: